| Sign In | Join Free | My infospaceinc.com |
|
Brand Name : ZONEWU
Model Number : LW117S-NO3
Certification : CE/RoHS
Place of Origin : Xiamen
MOQ : 1
Price : Contact Us
Payment Terms : T/T
Supply Ability : 500
Delivery Time : 31 days
Packaging Details : 37x26x5 cm
Product Name : LoRaWAN Solar Water Quality Nitrate Ion Sensor
Power Supply : Solar Powered + Li-ion Battery
Weight : 230g
Accuracy : ± 5% or ± 2 mg/L of the reading, whichever is greater; ±0.5℃
Temperature Compensation : Automatic temperature compensation (Pt1000)
Working Conditions : 0~40℃,≤0.2MPa
Electrode Usage Cycle : 1-2 years
Transmitter Line length : Default 5m (other lengths can be customized)
Frequency : CN470/IN865/EU868/RU864/US915/AU915/ KR920/AS923-1&2&3&4
Mode : OTAA Class A/C
Communication Protocol : LoRaWAN,LoRa TDMA Networking
This solar powered water quality NO3 sensor has truly achieved a breakthrough upgrade of "no power supply, no wiring, and long-term monitoring". It integrates efficient photovoltaic power supply modules and high-sensitivity nitrate ion detection technology, providing an all-weather, zero electricity, and low maintenance online solution for nitrate in water quality for aquaculture, aquarium viewing, agricultural non-point source pollution monitoring, and river and lake ecological investigation. No need to replace the battery, no need to connect to the mains power, only sunlight or scattered light is needed for sustainable operation, completely bidding farewell to the traditional sensor's frequent battery replacement or difficulty in obtaining electricity in the field.
1. Green energy, ultra long battery life. Equipped with a built-in 3400mAh lithium battery and solar float charging, the battery life is ≥ 3 years under the default 30 minute reporting cycle. Please note that ion sensors have high power consumption and it is not recommended to set a too short reporting cycle. After the first use or complete power outage, the power supply needs to be activated through the TYPE-C interface.
2. High precision monitoring, stable and reliable. The nitrate measurement range is 0~100.0 mg/L or 0~1000.0 mg/L (default 0~100 mg/L), with an accuracy of ± 5% or ± 2 mg/L of the reading (whichever is greater), and a resolution of 0.1 mg/L. Built in temperature compensation (0-40 ℃) ensures data stability in both freshwater and seawater scenarios. The service life of the electrode is about 1-2 years. If it is not used for a long time, it should be stored dry and covered with a protective cap.
3. Flexible installation and intelligent operation and maintenance. The sensor probe needs to be installed at an angle of ≥ 15 ° and cannot be inverted or placed horizontally. Remote restart, modification of reporting cycle, and zero/slope/temperature calibration can be performed through LoRaWAN downlink commands (standard solution needs to be prepared). Support OTAA network access, data is reported in Modbus hexadecimal format (starting byte C0, sensor type 11), and after parsing, NO ∝⁻ (mg/L), temperature (℃), and voltage (V) can be obtained.
4. Anti interference design, widely applicable. The manual provides a detailed list of interfering ions (such as ClO ₄⁻, I ⁻, NO ₂⁻, etc.) to help users assess data reliability in complex water quality. Before use, the electrode needs to be soaked in tap water for 24 hours to activate and cleaned regularly; If there is an error that cannot be calibrated, please replace the electrode in a timely manner.
| Power Supply |
Solar Powered + Li-ion Battery (0.88W solar panel+3.7V/3400 mAh Li-ion battery) |
|
| LW117S Weight | 230g | |
| Range and Resolution | 0~100.0 mg/L(default) | 0.1mg/L,0.1℃ |
| 0~1000.0 mg/L | 0.1mg/L,0.1℃ | |
| Accuracy | ± 5% or ± 2 mg/L of the reading, whichever is greater; ±0.5℃ | |
| Temperature Compensation | Automatic temperature compensation (Pt1000) | |
| Working Conditions | 0~40℃,≤0.2MPa | |
| Electrode Usage Cycle | 1-2 years | |
|
Electrode Transmitter Line length |
Default 5m (other lengths can be customized) | |
| Frequency |
CN470/IN865/EU868/RU864/US915/AU915/ KR920/AS923-1&2&3&4 |
|
| Mode | OTAA Class A/C | |
| Reporting cycle | 30min(Default ) | |
| Battery Life |
≥3 years(Based on normal use conditions) Note: Due to the high power consumption of ion sensor, it is not recommended to use short cycle data reporting. |
|
| Communication Protocol | LoRaWAN,LoRa TDMA Networking | |
|
Equipment information (Reference) |
AppEUI:331341E186891989 DevEUI:aaaa202404150001 AppKey:5572404c696e6b4c6f526132330313823 MAC Version: LoRaWAN 1.0.3 |
|
Single gross weight: 1.200 KG
Single package size: 37x26x5 cm
Product Display:



1.Each production process is inspected by dedicated personnel, with strict controls at every stage to ensure stable and reliable product quality.
2.Professional engineers oversee the entire quality inspection and control process, enabling closed-loop management from raw material sourcing to finished product.
3.The product has obtained multiple authoritative certifications, including CE, RoHS, and metrological certification, complying with stringent domestic and international standards.



1.Are you manufacture?
A:Yes,we are Tranmitter manufacturer and exporter in China with more than 10 years of CE,ROHS,FCC,ISO and 11 patents experience.
2.Do you offer OEM services?
A:Yes,we can provide you with OEM services and design housings and logos.
3.DO you offer free samples?
A:Sorry,we don't offer free samples.After ordering in bulk,we will deduct the sample fee from the second order.
|
|